Pre-possession checklist: every check, and why it matters
The 60-point field checklist our team uses at flat and house handovers, zone by zone. Use it yourself, or let us run it with the instruments it needs.
Quick answer
What should I check before taking possession of a flat?
Check documents and carpet area, then every room: walls and cracks, hidden damp on walls shared with toilets, hollow floor tiles, windows, earthing on every socket, the RCCB and distribution board, toilet floor slope and waterproofing, kitchen leaks, balcony slope and railing, and common areas. Record each defect with a photo and give the list to the builder before you sign.
How each point is marked
OK:Meets the standard.
Minor:Fix before possession. −2 points.
Major:Safety, leakage or structure. −10 points and the team lead is called on site.
N/A:Not present in this home. No effect on the score.
· Be polite with the builder’s staff. Record facts; don’t argue on site.
· Don’t sign builder documents or accept keys until the list is agreed.
· Let the builder’s representative operate mains, gas and lifts. Never open gas lines.
· Compare moisture readings against a known dry wall in the same flat.
· Photograph every defect twice: one wide, one close-up with its tag visible.
Z0Documents & area
Done first, with the builder’s representative where present.
DOC-01
Possession / handover letter
We read the letter and note its date and flat number. We never sign builder documents for you.
Visual
Why it matters: The possession date starts your defect-liability period under RERA. A wrong date or flat number causes trouble later with claims, registration and loans.
DOC-02
Occupancy Certificate (OC) status
We ask whether the OC has been issued for this tower and note any reference shown.
Visual
Why it matters: Without an OC, permanent water and power connections, registration and resale can be delayed. You should know before you move in, not after.
DOC-03
Keys counted and labelled
Main door, bedrooms, balcony, toilets, letter box and meter room.
Hand
Why it matters: Missing keys mean lock changes at your cost, and unknown copies are a security risk on day one.
DOC-04
Carpet area matches the agreement
Every room is laser-measured wall to wall and totalled against the agreement. We flag a shortfall of more than 3%.
LaserTape
Why it matters: You pay per square foot. Room-by-room measurement leaves out internal wall thickness, so a small gap is normal. A large gap is money, and it can only be raised before you accept the flat.
DOC-05
Electricity meter in your name / flat number
We note the meter number and opening reading.
Visual
Why it matters: A wrong meter means paying someone else’s bill. The opening reading protects you from construction-period consumption.
DOC-06
Live water supply in every tap
Each tap runs for 30 seconds. We note colour, smell and flow.
Water
Why it matters: Discoloured or smelly water points to rusty lines or tank problems. These are cheaper to fix before you move in.
Z1Main door & entry
ENT-01
Door sits square with even gaps
Even gap of about 3 mm on all sides, no rubbing at the bottom.
TapeVisual
Why it matters: A door that rubs today jams in the monsoon when wood swells. Uneven gaps also let dust and insects in.
ENT-02
Lock, latch, peephole, stopper
Locked from both sides with every key. Peephole clear.
Hand
Why it matters: Your main door is your security. A stiff lock fails at the worst time.
ENT-03
Bell / video door phone works
Pressed from outside, heard inside.
Hand
Why it matters: Often wired last and left untested. Fixing it later means chasing cables through finished walls.
ENT-04
Frame and shutter finish
No cracks, termite marks, swelling or polish runs.
Torch
Why it matters: Termite trails or swelling at the frame foot point to damp or infestation that spreads to wardrobes and kitchen units.
Z2Living & dining
The wall, floor, window and socket checks repeat in every room.
LIV-01
Walls straight and plumb
A 2 m spirit level on each wall. We flag gaps over 3 mm.
Spirit level
Why it matters: Wavy walls show under lights, make wardrobes and kitchens hard to fit, and often mean rushed plastering.
LIV-02
Paint and plaster finish
A torch swept at a low angle shows patches, bubbles and hairline cracks.
Torch
Why it matters: Bubbling paint on a new wall usually means moisture behind it. Fresh paint is where defects hide at handover.
LIV-03
Cracks classified
Hairline under 0.3 mm is Minor. Over 1 mm, or diagonal from a corner or opening, is Major.
TapeTorch
Why it matters: Hairline shrinkage cracks are cosmetic. Wide or diagonal cracks can mean movement. They must be examined before you accept the flat, not after the first summer.
LIV-04
Hidden damp behind walls
Walls shared with a toilet or kitchen are read with a moisture meter and thermal camera, against a known dry wall.
Moisture meterThermal camera
Why it matters: Damp behind fresh paint is invisible on handover day. It shows up as peeling and mould within months, usually in the first monsoon.
LIV-05
Floor tiles: hollow, cracked, uneven
Every tile is tapped in a grid. A hollow sound is marked with tape.
Tap hammerSpirit level
Why it matters: Hollow tiles have poor bedding underneath. They crack or lift within the first year, and the fix means breaking them out.
LIV-06
Tile joints and skirting
Grout filled, edges level (lippage under 1 mm), skirting firm.
VisualHand
Why it matters: Open grout lets mopping water under the tiles. Raised edges chip and trip people.
LIV-07
Windows / sliding doors
Slid full length, locked; glass, rubber seal and mesh checked.
Hand
Why it matters: Poor seals let rain in during the monsoon and hot air in during summer, which raises your AC bills.
LIV-08
Switches and sockets
Every point is tested for power, polarity and earth.
Socket tester
Why it matters: Reversed polarity or a missing earth is a shock hazard and damages appliances, and the manufacturer can refuse a warranty claim.
LIV-09
AC point ready
16 A socket, core-cut for the pipe, drain outlet present.
Visual
Why it matters: Without a core-cut and drain, installing an AC means drilling through finished walls, and the drain water ends up on your wall.
Z3Kitchen
KIT-01
Platform level, granite joints sealed
Level across the top. No cracks, chips or open joints.
Spirit levelVisual
Why it matters: Open joints let water into the base below, which swells the cabinets and attracts pests.
KIT-02
Sink drains fast, no leak below
Sink filled and released, with a torch under it while it drains.
WaterTorch
Why it matters: A slow leak under the sink rots the cabinet base unseen, often within weeks of the modular kitchen going in.
KIT-03
Tap flow and pressure
A 1-litre jug should fill in about 10 seconds.
Water
Why it matters: Low pressure on day one means airlocks, undersized pipes or a pump problem. These get worse when the tower fills up.
KIT-04
Wall tiles behind the platform
Tap-tested; grout complete; no gap at the platform edge.
Tap hammer
Why it matters: The gap at the platform edge is where water and cockroaches get in.
KIT-05
Appliance sockets earthed
16 A points for fridge, microwave and RO, all tested.
Socket tester
Why it matters: Kitchen appliances are the heaviest and wettest loads in the home. An unearthed socket here is the most dangerous one.
KIT-06
Chimney / exhaust and gas (PNG) points
Provision present and capped. Gas lines are never opened by us.
Visual
Why it matters: A missing chimney cut-out or PNG provision is a builder item. After possession it becomes your renovation.
KIT-07
Damp on kitchen walls
Scanned around the sink and below the platform.
Moisture meterThermal camera
Why it matters: Concealed pipe joints that weep are found now by a meter, or later by mould behind your cabinets.
Z4Bedroom
Every bedroom also gets the Z2 wall, floor, window and socket checks.
BED-01
Wall shared with the toilet is dry
Scanned full height with a moisture meter and thermal camera.
Moisture meterThermal camera
Why it matters: This is the most common hidden leak in new flats. The bathroom’s waterproofing fails and the bedroom wall shows it.
BED-02
Window frame sealed
Thermal imaging shows cold streaks where the frame has gaps.
Thermal camera
Why it matters: A gap you can’t see becomes a damp patch under the window after the first heavy rain.
BED-03
Door, lock and stopper
Closes freely, locks, no rubbing.
Hand
Why it matters: Bedroom doors swell first in humid months. If it rubs now, it will stick then.
BED-04
Wardrobe (if provided)
Shutters aligned, hinges firm, no swelling.
Hand
Why it matters: Swelling at the base means the board got wet during construction. It spreads and delaminates.
BED-05
AC point ready
Socket, core-cut and drain outlet.
Visual
Why it matters: The bedroom AC runs longest. A missing drain means water staining down your wall.
BED-06
Floor tiles tap test
Grid tap; hollow tiles marked with tape.
Tap hammer
Why it matters: Hollow tiles crack under a bed or wardrobe, and then the furniture has to come out for the repair.
Z5Toilet
The highest-risk room. We take our time here.
TLT-01
Floor slope to the drain
A bucket is poured. No water should be left standing after 2 minutes.
Water
Why it matters: Ponding water finds its way through grout and into the walls and the flat below. It is also a slip hazard every day.
TLT-02
Drain and WC flush
Flushed 3 times; WC base checked for seepage; WC fixed firmly.
WaterHand
Why it matters: A seeping WC base soaks the floor slab and shows up as a stain on your neighbour’s ceiling, and the complaint comes back to you.
TLT-03
Hot/cold mixer, health faucet, shower
Each run for flow; joints checked for drips.
Water
Why it matters: A drip at a concealed mixer joint runs inside the wall for months before anyone sees it.
TLT-04
Geyser point earthed
Socket tester; the geyser’s MCB located in the distribution board.
Socket tester
Why it matters: A geyser in a wet room without earthing is the single most dangerous electrical defect in a home.
TLT-05
Exhaust fan works
Paper test: the fan should hold a sheet.
Hand
Why it matters: Weak extraction means condensation, mould on the ceiling and a toilet that never dries.
TLT-06
Waterproofing: walls outside the toilet
Moisture meter and thermal camera on the other side of every toilet wall.
Moisture meterThermal camera
Why it matters: Waterproofing can’t be seen once it is tiled over. Reading the wall outside is the only non-destructive way to know it works.
TLT-07
False ceiling / ceiling dry
A torch and thermal camera above the false ceiling. Stains mean an upper-floor leak.
TorchThermal camera
Why it matters: A leak from the flat above is the builder’s to fix now. After possession it becomes a dispute between neighbours.
TLT-08
Tiles: hollow, grout gaps
Floor and walls tap-tested; grout fully filled.
Tap hammer
Why it matters: Every open grout line in a toilet is a path for water to reach the waterproofing layer, and to get past it.
Z6Balcony & utility
BAL-01
Railing height and strength
At least 1 m high; pushed firmly, no movement.
TapeHand
Why it matters: Child safety. A loose railing is a Major item regardless of score.
BAL-02
Floor slope and outlet
Water is poured. It must flow to the outlet, never towards the room.
Water
Why it matters: A reverse slope sends rainwater under your balcony door and into the living room in the first heavy shower.
BAL-03
Washing machine inlet and drain
Tap point and drain outlet present and working.
Water
Why it matters: Without a proper drain, the machine floods the balcony or the pipe has to run across the floor.
BAL-04
External wall and sill cracks
Torch along the sill and wall junctions.
Torch
Why it matters: Cracks at sills let rain into the wall, which comes out as damp inside the room.
Z7Electrical & services
The builder’s representative operates the main switch.
ELE-01
Distribution board labelled
Every MCB labelled to a room or circuit.
Visual
Why it matters: In an emergency you need to cut the right circuit in seconds, not by trial and error.
ELE-02
RCCB trips on test
The test button is pressed. It must trip.
Hand
Why it matters: The RCCB is what saves a person from a fatal shock. A failed one gives no warning until the day it matters.
ELE-03
Hot spots in the DB under load
Geyser and lights run for 10 minutes, then the DB is thermal-scanned. Any terminal 10 °C hotter than others is flagged.
Thermal camera
Why it matters: A loose or undersized connection heats up. With summer AC load it trips, melts, or starts a fire.
ELE-04
All lights and fans work
Every switch and fitting; fans at all speeds.
Hand
Why it matters: Dead points often mean a broken concealed wire. That is a builder fix now and a wall-chasing job later.
ELE-05
Earthing on every socket
Every socket is tested, and the total failures are recorded.
Socket tester
Why it matters: Earthing protects people and appliances. One failed socket often means a whole circuit is not earthed.
ELE-06
Power backup / inverter provision
Compared with what the brochure promised.
Visual
Why it matters: Backup wiring is far cheaper to correct before possession than to retrofit.
Z8Common areas (quick)
COM-01
Lift working, emergency button
One ride; alarm and phone respond.
Hand
Why it matters: An emergency button that rings nowhere is a real risk for children and elders.
COM-02
Fire safety on this floor
Extinguisher in date, hose reel, exit signs, sprinkler if specified.
Visual
Why it matters: Fire safety is part of what you paid for, and it matters to your insurer.
COM-03
Allotted parking slot
Slot number matches the allotment letter.
Visual
Why it matters: Parking disputes are hard to unwind once another owner is using the slot.
COM-04
Staircase and corridor
Lights, railing, no seepage in shaft walls.
Torch
Why it matters: Seepage in a service shaft beside your flat travels into your walls next.
Z9Terrace, exterior & services (houses and villas)
Added for independent houses, villas, builder floors with a terrace, and penthouses.
EXT-01
Terrace slope and rainwater outlets
Water test across the terrace; every outlet clear and grated.
Water
Why it matters: Ponding on a roof slab is the main cause of ceiling leaks in top-floor rooms.
EXT-02
Terrace waterproofing and parapet
Visual and moisture readings on the slab below; parapet and coping cracks.
Moisture meterThermal cameraTorch
Why it matters: Roof leaks cost the most to fix of any defect. The ceiling below shows it first.
EXT-03
Overhead tank and sump
Access, lids, overflow, float valve and any visible leakage.
VisualWater
Why it matters: An open or leaking tank contaminates drinking water and soaks the structure around it.
EXT-04
External walls
Cracks, damp patches and plaster hollowness on the outside.
TorchTap hammer
Why it matters: External cracks take in rain all monsoon and show up as damp on the inside.
EXT-05
Internal staircase and railings
Riser heights consistent, railing firm, treads not hollow.
TapeHandTap hammer
Why it matters: Uneven risers cause falls, and loose railings are a child-safety Major.
EXT-06
Drainage chambers and boundary
Inspection chambers open and flowing; gate and boundary wall sound.
WaterVisual
Why it matters: Blocked chambers back up into ground-floor toilets during the first heavy rain.
Bigger homes: how the checklist grows
Every extra bedroom repeats the Z2 and Z4 checks, every extra toilet repeats Z5, and independent houses, villas, penthouses and builder floors with a terrace add Z9.
1 BHK
50+ checks
Studio and 1 BHK apartments
2 BHK
65+ checks
2 BHK apartments and builder floors
3 BHK
85+ checks
3 BHK apartments, with a utility or servant room
4 BHK+, villa or house
105+ checks
Large apartments, penthouses, builder floors with a terrace, villas
A checklist is only as good as the instruments behind it. Damp behind fresh paint, a missing earth and a hot terminal can’t be seen. That is why our team carries a moisture meter, a thermal camera and a socket tester to every visit.